The high voltages can be used 48 hours after launch.
Description | tc | tm | params | VxWorks |
Description | tc | tm | params | VxWorks |
coninued on next page | ||||
Specify Vmcp23 ramp parameters |
h7140 | h510=``mcp23'' h160=1400 h175=``off'' | tc_det_load_hv_ramp_params 3, 1400, 25, 0 | |
Perform ramp | h5140 | tc_det_start_hv_ramp | ||
Wait up to 120s for event | 92100 | h7000=``mcp23 ok'' | ||
Specify Vmcp1 ramp parameters | h7140 | h510=``mcp1'' h160=550 h175=``off'' | tc_det_load_hv_ramp_params 2, 550, 25, 0 | |
Wait up to 120s for event | 92100 | h7000=``mcp1 ok'' | ||
Perform ramp | h5140 | tc_det_start_hv_ramp | ||
Specify V cathode ramp parameters | h7140 | h510=``cathode'' h160=2 h175=``off'' | tc_det_load_hv_ramp_params 1,2,25,0 | |
Perform ramp | h5140 | tc_det_start_hv_ramp | ||
Wait up to 10s for event | 92100 | h7000=``cathode ok'' | ||
Specify V cathode ramp parameters | h7140 | h510=``cathode'' h160=396 h175=``off'' | tc_det_load_hv_ramp_params 1, 396, 25, 0 | |
Perform ramp | h5140 | tc_det_start_hv_ramp | ||
Wait up to 120s for event | 92100 | h7000=``cathode ok'' | ||
Specify Vmcp1 ramp parameters | h7140 | h510=``mcp1'' h160=520 h175=``off'' | tc_det_load_hv_ramp_params 2, 520, 25, 0 | |
Perform ramp | h5140 | tc_det_start_hv_ramp | ||
Wait up to 60s for event | 92100 | h7000=``mcp1 ok'' | ||
Specify Vmcp23 ramp parameters | h7140 | h510=``mcp23'' h160=1700 h175=``off'' | tc_det_load_hv_ramp_params 3, 1700, 25, 0 | |
Perform ramp | h5140 | tc_det_start_hv_ramp | ||
Wait up to 60s for event | 92100 | h7000=``mcp23 ok'' | ||