FM TV Test ISAS 19/03/06 - 03/04/06 Sunday 19 March 06 JAT/HH/MCRW 16:57 EIS on ICU_N15V Hi warn (0xCC, -13.99v) Change limits in egse 17:00 Upload health monitor, enable health monitor Emergency mode (0x00E51098 code) Recover to manual CM_POS 0xAABC CM_POS moved to 0xCFEC, 0x858F, 0xAABE during sequence 17:45 Change to auto 18:12:36 Change to manual (aborts sequence 64) 19:24 Copy eeproms 4-7 to 0-3 ok 19:45-ish EIS off ********************************************************************** Monday 20 March 06 09:00 Morning meeting - New health monitor table required urgently - 50 kbps & 100 kbps sequences actually less than half rate - compression accidently left on - change sequences 10:43 New health monitor table uploaded and test successfully 10:47 Standby 10:48 EIS off ********************************************************************** Tuesday 21 March 06 HH/JAT/BS/MCRW 09:15 Morning meeting - 5x10-3 mbar pressure - Some data missing from DHU (DR) Spacecraft clock reset by command sometime during the night ********************************************************************** Wednesday 22 March 06 04:00 JAT EIS switched on. Startup sequence run to input heat. 1 PZT_SGO 0x010E (1.7v) 48 CM_POS 0xAABE 49 SS_POS 0xC053 (256") 55 PZT_DRV 0x3DED (-9.6 v) High warn on ICU_P15V (incorrect limit set in egse - change to 14.13) 09:15 Morning meeting - Spacecraft time reset during night JAT leaves after meeting HH/TW/BO/MCRW Notice that instrument packet timestamp different from hk1 timestamps 14:53 Spacecraft commanding, hk stops from ground (Changing from direct cable to radio) 14:55 Hk resumes 15:25 Update operational heater settings 15:30:07 Op heaters back on Data: st_data_2006_03_22_1455072990 MBus current 1.332 (0x90) Lowest mhc temp hz_t14 5.28 (hz_t0_16 3.13) 15:33:15 mech enable stat:B183 Can't run find shutter index, mhc temperatures too low. Don't know whether we can run light top/bottom - can leds be turned on below 10 degrees? Want to look at dust pattern on ccds. 16:30 Shutter motor temp 10.56, ss motor 10.24 hz_14 6.3, t0_(16) 4.14 16:30:30 Find shutter index Ack, 53 shutter opt ms 0, 54 0x7712 (30482) 16:31:47 load init obs table dump 16:35 upload obs table dump 16:41 select seq 50 (san ni)??? 16:41:18 auto 01c9 c66b shutter open time seq 52 01c9 c69f shutter open seq 53 mirror temps 23 9.07, 24 9.11, 25 8.8 xband data to be dumped at 19:00 01c9 c46f shutter open seq 56 seq 56 mhc vf invalid then valid 16:55:30 sequence stops ok 59 qcm_rd_ms 0x006e 60 qcm_rd_ls 0xae08 17:00 evening meeting - MDP/DHU time difference due to operational error during time reset - Hiro raised questions about out-gassing charts 17:30 QCM1 temperature ~ 35C => position near mhc box causing this => not good for measurements of grating etc... Data: /data/eis/fm/data/sdtp/st_data_2006_03_22_1455072990 then /data/eis/fm/data/sdtp/st_data_2006_03_22_1707589990 Late openeing new file? hk off for only a few minutes, why such a long delay in opening new file? 17:40 manual clear error 20:38:05 select sequence 107 (fmir/qcm test) 20:38:16 auto missed qcm1 qcm2 59 qcm_rd_ms 006e 60 qcm_rd_ls 23c9 qcm1 59 qcm_rd_ms 005e 60 qcm_rd_ls 3a80 qcm2 59 qcm_rd_ms 006e 60 qcm_rd_ls 23ae qcm1 59 qcm_rd_ms 005e 60 qcm_rd_ls 3c85 qcm2 59 qcm_rd_ms 006e 60 qcm_rd_ls 20c8 qcm1 (missed - having a smoke) 59 qcm_rd_ms 60 qcm_rd_ls qcm2 59 qcm_rd_ms 006e 60 qcm_rd_ls 1db5 qcm1 59 qcm_rd_ms 005e 60 qcm_rd_ls 409c qcm2 59 qcm_rd_ms 006e 60 qcm_rd_ls 1d38 qcm1 59 qcm_rd_ms 005e 60 qcm_rd_ls 40ca qcm2 59 qcm_rd_ms 006e 60 qcm_rd_ls 1db5 qcm1 005e 42a6 21:41:49 abort sequence 21:42:15 select seq 109 21:42:25 auto shutter abort (8) 66 nack 2 68 ec_ms 0x0C3B 69 ec_ls 2 72 status code 0xB19F 67 cmd hdr 0x6006 error code 2 = command not enabled No explanation for command 6006... 58 H_QCM_ST 0x1nnn qcm1 still on? Conflict with qcm on and trying to move the shutter? 22:17:21 qcm off 22:18:13 select seq 109 22:18:35 auto sequence running ok Still no idea about cmd hdr 6006 though (data file st_data_2006_03_22_2007589240) E-mail from Khalid explains 6006 22:31:43 Realize that hk1 packets are being sent at the rate of 2 a second now so the time between opening archives has increased. **************************** Thursday 23 March 06 9:15 Morning meeting - J-side ups fail 12-1 am but no effect on testing - EIS temps average 20C so will change to intermediate duty cycle - (10W -> 13W -> ) - No problems reported for EIS - System side mistake in S-band/X-band setting re tlm packet timestamping - System thinking of changing to X-band - Thermal balance condition to be determined & reported this evening - Thermal balance to be maintained all day HH/urimi/JAT/BS/MCRW 09:42 manual 09:42:58 select 107 09:43:17 auto seq 107 running mhc params: 23 mir base 3ca4 21.5 24 mir pzt 3ca3 21.43 25 mir mtr 3c9d 21.34 61 qcm1 temp 13de 62 qcm2 temp 127c data file: st_data_2006_03_23_0807586230 10:40 Manual QCMs off Heaters off 10:46 Set heaters to 9.5W 10:47:55 Heaters on data file: st_data_2006_03_23_0807586230 10:48:38 qcms off 10:49:02 Run seq109 MAIN/MDP->DHU IMG_TLM_CNT (units of 512 bits) (update every 2 seconds) data rate is ~ 10kbps (calculated 113kbps...) 11:32 manual 11:33 select seq 50 run xband realtime contact (./TLMUSER_REAL_HiX) auto 11:50-ish xband finish 11:50:30 manual clear errors 11:51:10 select sequence 109 11:51:24 auto Quicklook at realtime xband data - some doesn't look right data: expect get header data md_data_2006_03_23_1134037570 seq.50 seq.50 seq.50 md_data_2006_03_23_1135412900 seq.51 seq.51 seq.53 md_data_2006_03_23_1137513360 seq.52 seq.52 seq.50 md_data_2006_03_23_1140013760 seq.53 seq.53 seq.53 md_data_2006_03_23_1142114180 seq.54 seq.54 seq.50 md_data_2006_03_23_1144214600 seq.55 seq.55 seq.53 md_data_2006_03_23_1146315020 seq.56 seq.56 ??? ll.19 md_data_2006_03_23_1146477580 seq.57 seq.57 ??? ll.19 md_data_2006_03_23_1147040140 seq.58 seq.58 ***NOTE: boot mode mbus current needs better check in status monitor. Depends on temperature? 17:15 Evening meeting 18:03:50 manual 18:05 seq 109 auto xband real-time? 20060323180400 no 18:46 manual clear error 18:48:13 upload obstbl - seq 109/ll 28 altered to 8 windows 18:48:32 dump obstbl 18:49:28 select seq 109 18:49:46 auto ************************** Friday 24 March 06 NOTE; HM settings as per Draft of JATs doc have been used by HM since power up. 9:15 Morning meeting - Electrical check and switch from channel A -> B scheduled at 10.00 - Estimated to take 1 hour for changeover - Power down instruments - what order? - Power up - what order? - Restart op commanding - OTS internal testing scheduled for 10:30 10:12:02 op stop op disable 10:15:28 manual 10:15:41 clear error 10:18:31 op htrs off 10:19:04 qcm testing temps ~20 qcm 1 59 005e 60 8bc6 10:20 clear icu error qcm off qcm2 59 006d 60 6cfe clear error qcm off 10:22:37 vac gauge off 73 096f -> 3ffb 10:23:30 standby 10:24:34 bakeout ccda -28.07 ccdb -29.57 other instruments to power down while we bake data: st_data_2006_03_24_0807537640 10:32 ccda -22.74 ccdb -23.98 10:37 ccda -20.43 ccdb -20.43 20:42 ccda -18.33 ccdb -19.35 10:44:30 duty cycle -5 10:45:03 standby ccda -17.36 ccdb -18.33 10:45:52 eis off 10:46:07 ciggie break 10:52:09 end of ciggie break 11:27:17 eis on cp eeprom 4 ccds -29.57 11:28:00 standby 11:28:47 clear error 11:29:04 disable health monitor 11:29:31 dump hktable 11:31:10 upload hktable 11:31:41 dump hktable 11:32 enable hm monitor p15v hi warn 1 packet (prob D6) enable mode change 11:33:13 bake out ccd a -29.57 ccdb -29.57 other instruments going on 11:42 ccda -22.74 ccdb -23.98 11:52 ccda -18.33 ccdb -19.35 12:01 ccda -16.43 ccdb -17.36 12:01:14 -5 duty cycle 12:01:40 standby 12:02:11 manual 12:02:50 exit default 12:03:17 load mhc code from eeprom data:st_data_2006_03_24_1107549320 12:05:33 ram mode abort clear icu error 12:06:58 upload mhc parameters dump mhc parameter table 12:07:38 wdog enable safe enable 12:08:40 vac gauge on (73 3ffd -> 0968) 12:10:10 upload op heater parameters dump parameters 12:11:16 op heaters on 10W setting 12:19 hk1 rate seems to have changed again - back to 1 second interval 12:39 data:st_data_2006_03_24_1239461450 cmir = aabc functional tests 13:12:56 enable mhc mechs (B183) 13:13:18 find shutter index (B19B) 13:13:54 shutter open for 30s (B19B -> B1AB -> B19B) 13:14:53 slit to 0 (C055 250" -> 004A 1") 13:15:49 slit to 250" (004a -> c02c) 13:16:30 clear error 13:17:05 load mhc params for icu 13:17:32 dump icu params from icu 13:17:49 move cmir (AABC -> CFED -> 8590 -> AABD) 13:22 clear error 13:22:20 fmir auto fmir auto 13:24 load/dump init obstbl 13:26:30 load/dump latest obstbl 13:33:37 turn off op heaters 13:34:15 load op heater parameters 7W 13:34:52 dump op heater parameters tc_fail_pkt 1, tc_fail_cmd_id 0xA, tc_failed_ec 0x7 (POOR) nack 1 ec_ls 0x0100 dump mhc ram command sent instead of param table 13:26:58 dump mhcpar 13:37:25 op heaters on 13:40:04 clear icu error data:st_data_2006_03_24_1409463470 15:04 sel seq124 and auto spacecraft power change tests (monitoring for increase in noise in instruments) 15:38:47 manual clear icu error 15:49:36 select seq 50 auto 15:56 Images look wrong seq.124 will not set camera parameters back again as it was aborted, seq.50 does not set x parameters in camera. Propose to abort to manual, reset camera, exit default, restart seq.50 16:00:42 manual camera soft reset exit default clear icu error 16:29 select seq 50 auto 16:46 sequence stops ok manual ckear icu error 16:49 select seq 107 (pzt/qcm) auto qcm1 59 005e 60 872c qcm2 59 006d 60 d597 qcm1 59 60 qcm2 59 006d 60 d9c0 qcm1 59 005e 60 86ef qcm2 59 006d 60 dce3 qcm1 59 005e 60 8805 qcm2 59 006d 60 df95 qcm1 59 005e 60 8811 qcm2 59 006d 60 e182 Evening meeting - Report of corrupt data, reason and fix 17:42 manual clear error select seq 109 auto 19:02:40 manual 19:05 op starts seq 109 22:00 HH reports corrupted data after restarting seq 50 (?) after running seq 124. This is due to the sequence not setting up the camera parameters properly (it relies on being the first sequence to run after camera power up). Fix sequences tomorrow *********************************************** Saturday 25 March 06 9:15 Morning meeting - 10:04 manual clear icu error 10:09 select seq 50 auto 10:18 manual clear icu error select seq 109 auto 10:21 manual cam reset exit default clear icu error select seq 50 auto 10:42 manual clear icu error Look at duff 23/03/06 data. Sequence descriptions for seq 55 onwards do not match the actual sequences... 16:37 select seq 109 auto 15:30 Evening meeting - Op stopped on schedule - EIS anomalous exposure testing, couldn't repeat bad images - S/c comms testing - FPP set to eclipse mode - OBU mode 4 started, eclipse mode simulated for battery simulation - XRT ccd bakeout followed by ops - Anomalous FPP status packet production investigated - SLA temperature concerns presented, procedure for cold case needs to be found - Survival testing starts monday, must have procedure before tuesday - Residual gas analyser found new HeII peak @ 5pm when pressure changed 7x10e-8 to 4x10e-7 torr - S/c comms system characterization changes larger than previous s/c report - Night/day simulations to start at 18:37, EIS continues seq 109 18:25 seq 108 running when we return from the meeting 18:28 manual clear icu error select seq 109 auto changing duty cycle to 7.25W data:st_data_2006_03_25_2040418960 21:05 change duty cycle manual dump mhc parameters op heaters off upload dump op heaters on select seq 109 21:08:51 auto *********************************************** Sunday 26 March 06 9:15 Morning meeting - Eclipse cycle testing continues. - Chamber pressure: large peaks and regular small peaks still seen as reported at the evening meeting. - Large peaks correspond to night cycles - battery discharge. - FPP survival heaters on - EIS image event reported as no concern to electronics health: sequence procedure problem, investigation continues. - 2 pm meeting scheduled for cold case ops. 10:00 Still running seq 109 Cold case operations meeting scheduled for 14.00 15:00 Cold case meeting with system (HH email) 17:50:35 op stop uplink new op 18:00:21 op start *********************************************** Monday 27 March 06 9:15 Morning meeting - He stable - No battery tests scheduled but time reserved for them - Cold case procedures reported - Emergency backfill procedures reported 10:31:45 op stop 10:55 Informed that cold survival test has been postponed until tomorrow while the battery/pressure issue is resolved 11:09:03 manual clear icu error 15:00 xband replay of mission data taken at 06:00 (seq50) using op gives bad data. Redo sequence 50 after camera reset to see if any difference 15:07:50 reset cam exit default clear icu error select seq 50 15:09:20 auto 15:23:13 Finishes 15:26:39 manual clear icu error 17:15 Evening meeting - OBA still in mode 4 - FPP op htrs on - EIS camera check sequences run - XRT no problem - Kosugi to send current state of testing *********************************************** Tuesday 28 March 06 9:15 Morning meeting - S/c in same condition as yesterday - Hiro prepared pressure/temp plots - Thruster valve -z axis causing the trouble? (A1 thruster) - Test prepared by system to bypass battery and simulate battery pwr profile to see pressure response - RCS spring valve leaking? - No other molecular species - Try out backup htrs on thrusters 11:10 Starting rcs/battery test 11:30 procedure from Hiro 13:00 Testing other valves at cold survival temperatures 13:30 Attempt to retrieve yesterday's data from yesterday 15:00 Available every 97 minutes so try 16:30 start time, 17:30 end time, ant-A Error 33 (bad input parameter) Try 15:00 to 18:00, ant-A Error 33 Try 0600 to 0700 ant-A Get data which starts halfway through seq 54 Data bad Try 18:00 to 19:00 ant-A Error 33 Try 16:00 to 17:00 ant-A Error 33 Try 16:45 to 17:45 ant-A Error 33 Try 08:00 to 09:00 ant-A Connects, receives hk1 packets only until 08:06:01 Try 22:10 to 23:00 ant-A Connects, gets data until 22:19:59 xband_replay.log: Opening /data/eis/fm/data/sdtp/md_data_2006_03_27_2219490250 0022 0 3 (255 255) Opening /data/eis/fm/data/sdtp/md_data_2006_03_27_2219499640 0024 0 3 (255 255) Opening /data/eis/fm/data/sdtp/md_data_2006_03_27_2219544780 0025 1 3 (2 3) All sequence 109 data Informed that DR dumps at 22:00 JST and use dump time during testing to get data So try again this evening. What happened to last night's DR dump remains unanswered. 18:00 Briefing meeting to present result of thruster tests and get permission from instruments to proceed with cold case 18:38 Cold case starting data:st_data_2006_03_28_1742029310 19:00 Attempt DR dump replay (data dumped 18:30) (./XBAND_REPLAY_BIG) Start 18:30, end 19:00, ant-A Status data only, stops at 18:39:59 19:12 Data: st_data_2006_03_28_1912028760 20:05 standby 20:07:30 mhc mk up htr off 20:07:55 mhc 28 pwr on 20:09:32 mhc 28 pwr off 20:10:07 mhc mk up htr on 20:14:14 mdp time out of limit (1 packet) (MDP off for a short while) mhc_if_err not cleared after procedure 20:17:03 mdp reset mdp off 20:27:30 sus_a, sus_b, sus_c temp 19.31, 15.94, 19.21 20:31:22 eis off (tcib) mdp power channel switch A->B data:st_data_2006_03_28_2044040650 21:08 str7 18.8 sus_a, sus_b, sus_c temp 18.49, 15.12, 17.98 21:11:04 mdp on 21:11:37 mdp run 21:13:46 eis on tci-b 21:13:56 cp sw 4 21:14:21 standby mbus 28i d6 p15v hi warn (several times) 21:15:10 cam mk up htr off 21:15 hm off mhc mk up hter on mdp off 21:18:30 str7 17.71 susa susb susc 18.09, 14.72. 17.98 21:28:30 str7 17.71 susa susb susc 18.09, 14.72. 17.57 21:57:30 str7 16.63 susa susb susc 17.28, 13.91. 17.16 22:19:00 str7 16.08 susa susb susc 16.87, 13.50. 16.34 22:50 str7 15.00 susa susb susc 16.07, 13.10. 15.53 22:53 Attempt DR dump replay (data dumped 18:30) (./XBAND_REPLAY_BIG) Start 18:30, end 19:00, ant-A Status data only *********************************************** Wednesday 29 March 06 08:39 str7 7.42 susa susb susc 1.37, 3.61. 2.08 9:15 Morning meeting 10:25 str7 6.88 susa susb susc 0.51, 2.46. 0.2 11:03:32 surv a -0.09 htr will come on soon 11:17 htr c on 11:24 a is on 12:31 str7 3.78 susa susb susc 3.72, 3.52. 10.54 htr a temperature cutoff should be 5 degC when this is reached htr a will turn off and later be disabled 13:41 sus a = 5.27 13:52:33 sus c down about to 10.64 (was 11 or 12) 14:14:10 disable htr a sus a, b, c = 3.89 2.84 3.61 (3.72 3.52 4.29 on J-side) 14:30 sus a, b, c = 3.13, 2.46, 2.46 ( on J-side) 16:17:20 sus c -0.25 (noticed) a -0.46 b 1.24 1 4.18 2 4.72 3 3.1 4 -19.94 5 -8.75 6 -0.67 7 5.26 16:39 small rise in sus c - htr c is on 18:46 sus b rising, htr b on 18:48 sus b just over 5 degC htr off sus b decreasing *********************************************** Thursday 30 March 06 08:59 sus a, b, c 4.27, -0.55, 9.89 (4.10, 0.12, 10.54 J-side) str 7 1.48 (-0.61 J-side) 15:15 Get 24/03 15:49:36 data from data recorder (xband replay) (Input time 17:50 -> 18:30) 17:00 Evening meeting 18:20 str7 -1.16 18:25 mdp on many warnings +15v mbus 28i hi err 2.123 A (wrap around?) 19:12:12 eis off str7 -1.16 icu1 -3.41 icu2 -2.81 htra 2.94 htrb -0.25 htc 9.75 str1 -3.96 2 -2.81 3 -3.61 4 -23.58 5 -15.46 6 -7.2 Switching s/c from system B to A 20:25 str7 -4.46 eis on eeprom 4 standby bakeout 20:41:36 bake -5% 28i red 20:42:10 standby 20:42:42 manual all mhc temps above -10 20:43:27 exit default 20:43:59 load mhc 20:46:16 ram mode abort 48 aabd 49 c04d 1 0188 55 3ded 72 status 3082 20:48:14 wdog enable 72 3082 -> b082 20:48:34 safe enable 72 status b082 -> b083 20:49:15 vac gauge on 73 3fff -> 0950 20:49:23 op heaters off 20:50:50 upload mhc htr parameters 13W setting dump table 20:51:21 op htrs on *********************************************** Friday 31 March 06 9:15 morning meeting Notes by Tom from FPP 17:00 Evening meeting 17:52:04 op htr off 17:52:30 qcm 1 on 59 qcm rd ms 005e 60 qcm rd ls7Ebb 17:53 clear icu error 17:53:40 qcm off 17:54:08 qcm 2 on 59 qcm rd ms 006d 60 qcm rd ls89E9 clear icu error 17:55:10 qcm off 17:55:49 vac gauge off 009A -> 3FFB 17:56:20 standby 17:56:56 bake out ccd a -5.9 ccd b -5.9 red on 28i 0xFA 2.285 orange on +15v D6 (14.12v) 18:01 ccd a -3.56 ccd b -4.00 Main bus 28i wrap around Phone call with jat CAM status 47 PSU_CAM_N8VI hi warn 0xFD 0.334A CAM status 46 PSU_CAM_P7VI hi err 0xFF 0.982A 18:44 ccda 33.57 ccdb 33.57 target 35.09, duty cycle 20% icu proc temp 6.38 19:18 ccda 34.08 ccdb 34.08 icu proc temp 6.00 *********************************************** Saturday 01 April 06 08:37 manual mode ccd a -5.50 ccd b -5.50 icu proc 7.97 all normal mhc 48 cm_pos AABD 49 ss_pos C04E 1 pzt_sgo 0061 55 pzt_drv 3DEC 9:15 moaning meeting 10:36:31 mdp time red (check for missed packet ~2800 packet number) st_data_2006_04_01_0952451420 op uploading (Quick check can't find error - maybe packet slightly delayed over network) No jump in ccsds packet timestamp IDL t = read_fits_data('/data1/eis/fits/status/2006_04_01/st_data_2006_04_01_0952451420_STS1.fits','MDP_TIME',10) IDL> help,t T LONG = Array[2779] plot: plot,t(1:2778)-t(0:2777) plot,t,/ynozero,xrange=[1300,1400] IDL> t1=t(1:2778)-t(0:2777) IDL> print,where(t1 gt 1050) 1307 IDL> print,t1[1307] 2049 IDL> print,t1[1306] 1024 IDL> print,t1[1308] 1024 MDP time adjust - need to look at time information in telecommand Should alter ccsds telemetry time too though??? 11:53:29 mech enable 72 status_code B083 -> B183 11:54:04 find shutter index 53 0 54 0x7655 72 B183 -> B19B 11:56:57 shutter open 53 0x0131 54 0x2f81 11:57:56 slit 0 C04E -> 0050 (1") 11:58:53 slit 0050 -> c037 (250") 48 cm_pos AABC 11:59 clear icu error 11:59:57 upload icu mhc parameter 12:00:21 dump parameter 12:00:45 move cmir AABC -> CFED 12:01:33 cmir rvs CFED -> 8590 12:02:35 cmir 8590 -> AABE 12:03:21 clear icu error 12:03:43 fmir auto 1 004e -> 0F6B 55 3dee -> 144E 12:04:29 fmir auto 1 01CE 55 3DDE 12:05:43 mech enable (B19F) 12:06:01 find shutter index 12:06:18 load init obs table 12:06:46 dump obs table 12:08:23 upload obs table 12:09:44 dump obs table 13:17 battery mode, seq 124 for noise measurements 13:20:15 select 124 auto ./TLMUSER_REAL_HiX ant-a 20060401132000 Data received 13:27 Realtime X band mode stopped ok 13:57:17 manual 13:58:00 clear icu error 13:58:33 select seq 50 auto data st_data_2006_04_01_1255264450 14:00 (seq 43) realtime contact ./TLMUSER_REAL_HiX ant-a 20060401140000 Data received 14:03:24 dr dump starting 14:09:21 realtime x band stopped ok All image data ok 14:15:20 seq_stat stopped ok 14:17:58 manual 14:18:18 clear icu error 14:58:14 select sequence 109 14:58:29 auto 15:20 op upload 15:56 manual 16:00:10 seq 107 running (from op) 16:05 sla motor temp 27.30 degrees, approaching 30 degree limit (HH observe) Decide to prepare to turn off op heaters to prevent this Notice there has been slit move to 2", which briefly raises the temperature. Slowly decreases. str temps 20.76 - 26.6 qcm1 005e 7956 qcm2 006d 07bd qcm1 005e 6ca4 qcm2 006d 099d qcm1 005e 6e13 qcm2 006d 096e 16:30:10 manual (op) qcm off (op) clear error (op) Max seen on sla temp 27.48 16:40:10 auto (op) seq 109 running manual commands to turn off op heaters 16:45:55 manual 16:46:13 clear icu error 16:46:27 op heater off 16:46:57 select seq 109 16:47:39 auto 20 ss motor temp 27.37 21 shutter motor temp 27.83 heater zone temps decrease 17:00 Evening meeting - OBS sequence A started am - Battery power shunt mode test - X-band telemetry test - OP started 15:30 - FPP op htrs ok - OTA currently in mode 9 (decontamination) - XRT no problem - EIS image tests performed ok - Op heaters off manually during sequence 109 - After meeting mode 8 (warm up) will start (sometime) - System will discharge battery before backfill. Will take 3 to 5 eclipse cycles - Emergency off procedures prepared - EIS op htrs on ~20:00 17:45 Battery discharging starts 18:47:00 op stop disable 19:10 manual clear icu error 20:01:23 mhc op htrs on mhc temps ~ 19 - 26 htrs 1 & 10 not showing as going on on J-side display 58 x1xx xxxx xx1x (0x402) 20:15 45 T14 19.32 20:25 45 T14 19.58 Going up slowly 20:35 45 T14 19.66 20:45 45 T14 19.94 20:48 58 h_qcm_st 0x202 (htr 10, at last) 20:52 58 h_qcm_st 0x408 (htr 1) *********************************************** Sunday 02 April 06 08:45 Manual Seq stat aborted Mode enable stat disabled mhc status code B19F seq 109 had been running As per request to Hiro (phone call early in the morning!) 09:06 mode enable 09:15 Morning meeting - Backfill procedures 10:37:37 move slit 8039 -> c041 (250"), 22 ss motor 34.57 peak (up from ~31) 12:03 launch mode start xrt stuff MW stuff IRU 12:34:56 Nothing happened 12:49:09 a,b,c htrs disable a htr 30.17 b htr 29.24 c htr 29.71 13:01:50 no sts packets eis off s/c off 13:04:40 a 29.22 b 28.76 c 29.24 7 36.21 13:06:40 a 29.22 b 28.76 c 29.24 7 36.21 13:07 Shroud cooling stopped 13:10 a 28.76 b 28.76 c 28.76 7 35.66 13:12 purge started a 28.76 b 28.76 c 28.76 7 35.66 13:17 a 28.30 b 28.20 c 28.20 7 35.66 13:22 a 28.30 b 28.30 c 28.30 7 35.12 13:23 10e-2 mbar 13:24:40 40k cryo pump 0.1 mbar 13:25:50 0.2 mbar 13:27 a 26.94 b 26.92 c 26.92 7 34.03 13:28:13 0.6 mbar 13:28:39 0.7 mbar 13:29 a 25.61 b 26.03 c 26.03 7 33.48 0.8 mbar 13:29:32 0.9 mbar 13:30:04 1 mbar 13:30:32 sus mode power 13:31:00 s/c components going on a 23.98 b 25.14 c 24.27 7 32.93 13:31:40 a,b,c htrs on 13:32:26 mdp on 13:33:00 a 23.04 b 24.27 c 23.84 7 32.39 *** To be filled in *** Str/sus temperatures 13:35:18 eis on no egse limit warnings eeprom 4 standby mode enable 13:36 turn on complete 14:55 Op heaters on (manual, run from rom) ~15:51 - 16:01 mir temp starts to rise (1.50 - 1.58) 17:00 Evening meeting Look at 39 mhc_hz_t8 (dip during evening meeting?) data:st_data_2006_04_02_1630368950 18:06:58 op htrs off 18:07:29 standby 18:07:41 eis off 18:30:54 last hk1 packet realtime sband stopped