Choose Guide Stars

The ICU is in ``science'' mode.

Description tc tm params VxWorks
Description tc tm params VxWorks
coninued on next page
Set the filter wheel number for the next exposure h7604   h280= filter_number tc_fw_filter filter
Move the filter wheel h5600     tc_fw_move
Wait up to 20s for TMPSU event report   92600 h7010=``fw @ req pos''  
Set the acquisition mode to low resolution windowed h7130   h110=``Lo Res Win'' tc_det_acq_mode 0
Load the window table parameters h7110   Table 7  
Start the load window table task h5110     tc_det_load_windows 1
Wait up to 30s for detector event report   92100 h7000=``win tab load''  
Send IC_INIT_EXP h7249     tc_send_command IC_INIT_EXP
Wait 5s        
Set the DPU frame time (in units of 1/1024s) h7236   h710= frame_time tc_set_frame_time frame_time
Set the exposure id h7238   h530= exposure_number tc_set_exp_no exposure_number
Load the memory windows h7242   Table 10 tc_prog_mem_wind `` file''
Load the science windows h7243   Table 11 tc_prog_sci_wind `` file''
Set the exposure duration (units = frames) h7237   h720= number_of_frames tc_set_exposure_time exposure_time
Set BPE binning 0 h7257   h540=``No binning'' tc_set_bpe 0
Start the detector integration task h5130     tc_det_start_int
Enable choose guide stars task h7251     tc_send_command IC_CHOOSE_GS
Wait up to 60s for DPU event report DA_EOT_CHOOSE_GS   92212    
Wait for priority science data (window data)   97401    
Wait for window table loaded event   92100 h7000=``win tab load''  
Stop integration   h6130   tc_det_stop_int

The ICU is in ``science'' mode.